4.3.2 Amplitude Modulation Submenu
In the Amplitude Mod submenu the internal amplitude modulation can be accessed. Use the rotary
knob to set the modulation rate between 1 Hz and 10 kHz.
Enable modulation by pressing the RF On/Off button.
Exit the submenu by pressing the menu key.
Figure 4-g Amplitude Modulation Submenu
4.3.3 Frequency Modulation Submenu
In the frequency modulation submenu the internal and external frequency modulation can be
accessed. Use cursor keys to change between internal and external modulation source and change
modulation parameters such as modulation rate, depth or sensitivity. Enable modulation by pressing
the RF On/Off button.
Exit the submenu by pressing the menu key.