16
Command Summary (-cont-)
Command
Keyboard
Shortcut
Parameter Range
Description
TRIGger
INternal,
EXternal, GAted,
ONe, FIre
Set trigger to external clock or
external trigger or gated or
single cycle (1 pulse) and Fire
to issue 1 pulse.
THREshold 0
3.5
Set threshold level to
parameter specified.
DISPlay KEv / VOlt Set display either keV or
Volt.*
EQUIvalent 100 - 9999 Set keV equivalent voltage.
CLAMp ON, OFf Set pulse clamping either on or
off.
RAMP EXEC
Execute ramp
RAMP
VBEGin
0
9.5 Set ramp start voltage**
RAMP
VEND
0.5 - 10 Set ramp stop voltage**
RAMP
KBEGin
0 - 9499 Set ramp start keV***
RAMP
KEND
5 - 9999 Set ramp stop keV***
RAMP
CYCLes
0 - 999 Set number of Ramp Cycles
RAMP TIME
30 - 900 Set ramp time.
SAVE
Path & Filename Save setting to a file
LOAD
Path & Filename Load saved setting to PB-5
NOTE:
* No Effect on REMOTE Display. Will only affect LOCAL Display.
** Start and Stop Voltage must have a minimum of 0.5 V difference.
*** Minimum and maximum value is affected by equivalent keV settings, the values must be
proportional to the Voltage equivalent.